Lightning surge testing, Major tests such as lightning surge testing

Service

Lightning surge testing

The Lightning Technology Center is the only one testing laboratory specialized for lightning in Japan. Several world-class test facilities are installed in this Center, which have been designed and operated by our own technologies based on OTOWA’s experiences for many years as lightning protection specialist. The research and development of lightning protection equipments are carried out and evaluation testing for the various types of electric devices are also made in this Center. In addition, our Center can provide testing service to the customer in accordance with JIS & IEC standards.

Main testing and test facilities

Main testing and test facilities

HIGH CURRENT IMPULSE GENERATOR
  • Typical wave shape : 10/350μs, 4/10μs, 8/20μs
  • Maximum applied current : 220kA(10/350μs), 100kA (8/20μs, 4/10μs)
HIGH VOLTAGE IMPULSE GENERATOR
  • Typical wave shape : 1.2/50μs
  • Maximum applied voltage : 1500kV
  • Maximum charging voltage : 1600kV
SIMULATION HOUSE FOR LIGHTNING TEST

The influence of lightning surge can be verified by using actual house, equipment, wiring and electric appliances.

COMBINATION WAVE GENERATOR
The equipment is applicable for carrying the limit test of the products and examining the permissible lightning current of electric products.
  • Impulse voltage 1.2 / 50µs 55kV
  • Impulse current 8 / 20µs 27.5kA
  • Impulse voltage 10 / 700µs 55kV
  • Impulse current 5 / 320µs 1375A
  • Impulse voltage 1.2 / 50µs 40kV
  • Impulse current 8 / 20µs 20kA
  • (IEC 61000-4-5)

ENVIRONMENTAL TEST CHAMBER / VIBRATION TEST EQUIPMENT

Strict environmental tests, vibration tests are repeated to assure the reliability of the products for long-lasting use in the field.

HIGH VOLTAGE IMPULSE GENERATOR

HIGH VOLTAGE IMPULSE GENERATOR

COMBINATION WAVE GENERATOR

COMBINATION WAVE GENERATOR

VIBRATION TEST EQUIPMENT

VIBRATION TEST EQUIPMENT

Related facilities / EXPOSURE TESTING FIELD

◇Kitadaito EXPOSURE TESTING FIELD(Okinawa)
This facility conducts long-term exposure tests of outdoor facilities, mainly for electric power and communications in a harsh natural environment for the purpose of developing superior products in Kitadaito Village, which is said to have the most severe weather conditions in the Okinawa Prefecture. As a result, it is a comprehensive exposure test site where durability evaluation and performance verification against things such as salt damage, wind, rain and ultraviolet rays can be conducted.
EXPOSURE TESTING FIELD

EXPOSURE TESTING FIELD